Opcode | Instruction | Op/En | 64-Bit Mode | Compat/Leg Mode | Description |
---|---|---|---|---|---|
0F 01 C8 | MONITOR | ZO | Valid | Valid | Sets up a linear address range to be monitored by hardware and activates the monitor. The address range should be a write-back memory caching type. The address is DS:RAX/EAX/AX. |
Op/En | Operand 1 | Operand 2 | Operand 3 | Operand 4 |
---|---|---|---|---|
ZO | N/A | N/A | N/A | N/A |
The MONITOR instruction arms address monitoring hardware using an address specified in EAX (the address range that the monitoring hardware checks for store operations can be determined by using CPUID). A store to an address within the specified address range triggers the monitoring hardware. The state of monitor hardware is used by MWAIT.
The address is specified in RAX/EAX/AX and the size is based on the effective address size of the encoded instruction. By default, the DS segment is used to create a linear address that is monitored. Segment overrides can be used.
ECX and EDX are also used. They communicate other information to MONITOR. ECX specifies optional extensions. EDX specifies optional hints; it does not change the architectural behavior of the instruction. For the Pentium 4 processor (family 15, model 3), no extensions or hints are defined. Undefined hints in EDX are ignored by the processor; undefined extensions in ECX raises a general protection fault.
The address range must use memory of the write-back type. Only write-back memory will correctly trigger the monitoring hardware. Additional information on determining what address range to use in order to prevent false wake-ups is described in Chapter 9, “Multiple-Processor Management‚” of the Intel® 64 and IA-32 Architectures Software Developer’s Manual, Volume 3A.
The MONITOR instruction is ordered as a load operation with respect to other memory transactions. The instruction is subject to the permission checking and faults associated with a byte load. Like a load, MONITOR sets the A-bit but not the D-bit in page tables.
CPUID.01H:ECX.MONITOR[bit 3] indicates the availability of MONITOR and MWAIT in the processor. When set, MONITOR may be executed only at privilege level 0 (use at any other privilege level results in an invalid-opcode exception). The operating system or system BIOS may disable this instruction by using the IA32_MISC_ENABLE MSR; disabling MONITOR clears the CPUID feature flag and causes execution to generate an invalid-opcode exception.
The instruction’s operation is the same in non-64-bit modes and 64-bit mode.
MONITOR sets up an address range for the monitor hardware using the content of EAX (RAX in 64-bit mode) as an effective address and puts the monitor hardware in armed state. Always use memory of the write-back caching type. A store to the specified address range will trigger the monitor hardware. The content of ECX and EDX are used to communicate other information to the monitor hardware.
MONITOR void _mm_monitor(void const *p, unsigned extensions,unsigned hints)
None.
#GP(0) | If the value in EAX is outside the CS, DS, ES, FS, or GS segment limit. |
If the DS, ES, FS, or GS register is used to access memory and it contains a NULL segment selector. | |
If ECX ≠ 0. | |
#SS(0) | If the value in EAX is outside the SS segment limit. |
#PF(fault-code) | For a page fault. |
#UD | If CPUID.01H:ECX.MONITOR[bit 3] = 0. |
If current privilege level is not 0. |
#GP | If the CS, DS, ES, FS, or GS register is used to access memory and the value in EAX is outside of the effective address space from 0 to FFFFH. |
If ECX ≠ 0. | |
#SS | If the SS register is used to access memory and the value in EAX is outside of the effective address space from 0 to FFFFH. |
#UD | If CPUID.01H:ECX.MONITOR[bit 3] = 0. |
#UD | The MONITOR instruction is not recognized in virtual-8086 mode (even if CPUID.01H:ECX.MONITOR[bit 3] = 1). |
Same exceptions as in protected mode.
#GP(0) | If the linear address of the operand in the CS, DS, ES, FS, or GS segment is in a non-canonical form. |
If RCX ≠ 0. | |
#SS(0) | If the SS register is used to access memory and the value in EAX is in a non-canonical form. |
#PF(fault-code) | For a page fault. |
#UD | If the current privilege level is not 0. |
If CPUID.01H:ECX.MONITOR[bit 3] = 0. |