Opcode1
Instruction | Op/En | 64-Bit Mode | Compat/Leg Mode | Description | |
---|---|---|---|---|---|
0F 01 /0 | Valid | Valid | Store GDTR to m. |
1. See the IA-32 Architecture Compatibility section below.
Op/En | Operand 1 | Operand 2 | Operand 3 | Operand 4 |
---|---|---|---|---|
M | ModRM:r/m (w) | N/A | N/A | N/A |
Stores the content of the global descriptor table register (GDTR) in the destination operand. The destination operand specifies a memory location.
In legacy or compatibility mode, the destination operand is a 6-byte memory location. If the operand-size attribute is 16 or 32 bits, the 16-bit limit field of the register is stored in the low 2 bytes of the memory location and the 32-bit base address is stored in the high 4 bytes.
In 64-bit mode, the operand size is fixed at 8+2 bytes. The instruction stores an 8-byte base and a 2-byte limit.
SGDT is useful only by operating-system software. However, it can be used in application programs without causing an exception to be generated if CR4.UMIP = 0. See “LGDT/LIDT—Load Global/Interrupt Descriptor Table Register” in Chapter 3, Intel® 64 and IA-32 Architectures Software Developer’s Manual, Volume 2A, for information on loading the GDTR and IDTR.
The 16-bit form of the SGDT is compatible with the Intel 286 processor if the upper 8 bits are not referenced. The Intel 286 processor fills these bits with 1s; processor generations later than the Intel 286 processor fill these bits with 0s.
IF instruction is SGDT IF OperandSize =16 or OperandSize = 32 (* Legacy or Compatibility Mode *) THEN DEST[0:15] := GDTR(Limit); DEST[16:47] := GDTR(Base); (* Full 32-bit base address stored *) FI; ELSE (* 64-bit Mode *) DEST[0:15] := GDTR(Limit); DEST[16:79] := GDTR(Base); (* Full 64-bit base address stored *) FI; FI;
None.
#UD | If the LOCK prefix is used. |
#GP(0) | If the destination is located in a non-writable segment. |
If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit. | |
If the DS, ES, FS, or GS register is used to access memory and it contains a NULL segment selector. | |
If CR4.UMIP = 1 and CPL > 0. | |
#SS(0) | If a memory operand effective address is outside the SS segment limit. |
#PF(fault-code) | If a page fault occurs. |
#AC(0) | If alignment checking is enabled and an unaligned memory reference is made while CPL = 3. |
#UD | If the LOCK prefix is used. |
#GP | If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit. |
#SS | If a memory operand effective address is outside the SS segment limit. |
#UD | If the LOCK prefix is used. |
#GP(0) | If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit. |
If CR4.UMIP = 1. | |
#SS(0) | If a memory operand effective address is outside the SS segment limit. |
#PF(fault-code) | If a page fault occurs. |
#AC(0) | If alignment checking is enabled and an unaligned memory reference is made. |
Same exceptions as in protected mode.
#SS(0) | If a memory address referencing the SS segment is in a non-canonical form. |
#UD | If the LOCK prefix is used. |
#GP(0) | If the memory address is in a non-canonical form. |
If CR4.UMIP = 1 and CPL > 0. | |
#PF(fault-code) | If a page fault occurs. |
#AC(0) | If alignment checking is enabled and an unaligned memory reference is made while CPL = 3. |